Ingress protection
Rose specifies IPX7 and Succulent specifies IPX6. One refers to temporary immersion and the other to powerful water jets. A stronger-sounding number does not answer every question about the seal.
Data behind the chart
| Claim or record | Exposure described | Source and status |
|---|---|---|
| IPX4 | Splashing water | Reference class for splashing water. |
| IPX6, Succulent | Powerful water jets | The retail specification gives the class without a product-specific worksheet. |
| IPX7, Rose | Temporary immersion under defined conditions | The retail specification gives the class without a specimen inspection or ingress log. |
| IPX8 | Continuous immersion under specified conditions | Reference class. Consult the conditions for the product concerned. |
| The Dirty Lemon | IPX7 in commissioning materials | No supporting immersion record supplied. Counted separately from retail specifications. |
| Observed product | Water exposure | Observable outcome |
|---|---|---|
| Vibratex Magic Wand Waterproof | Two baths, depth and time unreported | Reviewer describes the operating unit floating and vibrating. |
| PHANXY Bendable | Nozzle only, for a few seconds during cleaning | Reviewer describes running the nozzle in water, shaking out water and air-drying. |
One letter and one digit change the story
Two products in the same Cosara catalogue use the word waterproof and then specify different water tests. Rose gives IPX7 in its specification. Succulent gives IPX6. The distinction is easy to miss if the shopper scans only the short sales description. The seventh water numeral refers to temporary immersion in prescribed conditions. The sixth refers to powerful water jets. A bathroom contains several possible exposures, and neither the word waterproof nor the order of the numerals tells the whole story. This 2026 review checks what the two retail records actually say and sets out what a laboratory record would have to add.
The commissioning materials also associate IPX7 with The Dirty Lemon. They contain no dated specimen log, water depth, hold time or post-test inspection linked to that model. It occupies a separate row from the two manufacturer specifications. The difference between a quoted rating and a witnessed test becomes particularly important in a story billed as a torture test. The phrase suggests that a writer pushed samples to failure and recorded where the seals gave way. No such observations accompanied these three entries. The graphic consequently compares four kinds of exposure rather than assigning three products invented passes.
Decoding the X and the two types of water load
IEC 60529 describes degrees of protection provided by enclosures. In an IP marking the two positions cover different kinds of protection. The X in these examples means that a numeral for solid-object protection is unspecified in the marking. It leaves that particular aspect open. A reader who sees IPX7 therefore has a water classification to investigate, but no dust rating to copy into a review. Nor does the code identify the materials inside the case or how the manufacturer seals the joint between them. A moulded seam, a button membrane and an exposed charging contact can present very different engineering questions.
Jets and temporary immersion load an enclosure in different ways. A jet concentrates moving water in a direction that changes as it sweeps past a joint. Immersion exposes the enclosure to water pressure that varies with depth. Holding a sample at the bottom of a tank does not recreate the effect of a directed water stream. Conversely a successful jet test does not establish how the same product behaves while submerged. The class diagram labels the defining exposure for each row. Its open cells are an aid to reading the chart. They mark questions the particular column does not settle, including whether another class was tested separately.
IPX7 is often described for small enclosures as a half hour with the lowest point one metre below the water surface. The precise geometry in the standard matters, especially when the object grows taller. For a laboratory account, print which point on the sample supplied the depth reference. “One metre of water” could otherwise mean a metre above the top, a metre above the bottom or simply the depth of the tank. Those conventions do not always create the same pressure at the most vulnerable seam. IPX8 conditions likewise need the product's specified conditions alongside the class rather than a depth invented by the editor.
Checking the claim on the object that ships
A reporter can establish a good deal before introducing water. Match the model, revision and packaging to the manufacturer's specification. Photograph the rating on the unit or its accompanying instructions if present, identifying the location. A listing that says waterproof in a headline and gives a precise code in a specification should be quoted at its most informative point. If the instructions for care describe a narrower use, report the wording and request clarification. A familiar product name may persist across several revisions. Checking an old sample against a new listing without recording either version could make an apparent failure meaningless.
On Rose the retail specification includes both a timing claim for operation and an IPX7 claim. These belong to different tests. An hour of stated playtime cannot be used to extend a thirty-minute immersion condition. On Succulent the manufacturer's waterproof wording sits alongside an IPX6 specification. This tells an editor where to direct a request for the jet-test record. It does not create an immersion result for the product. The source table keeps both entries in the manufacturer's own class. Treating their short descriptions as interchangeable would lose the one field on the page that explains how the claims differ.
What two reviewers actually put in water
A firsthand review of the Vibratex Magic Wand Waterproof describes using it in two baths. The author observed it floating and vibrating. This is evidence that the reviewed specimen operated during those occasions. The report gives no measured depth, elapsed immersion interval or internal inspection. The twenty-minute figure mentioned for this model describes an automatic shutoff. Quoting it as twenty minutes of submersion would misidentify the event being timed. The product also differs from the Rose and Succulent models for which we inspected retail claims.
A second first-person account describes briefly submerging the nozzle of a PHANXY Bendable model while the device was running during cleaning. The reviewer describes the interval as a few seconds, followed by shaking out water and air-drying. This time the component and a rough duration are known. A submerged nozzle and a floating wand can both feature in a fair account of what consumers observed. Neither establishes a thirty-minute immersion of the complete enclosure or a result for an internal seal. In particular, the reported outcome cannot be moved from either named model to another product sold with a similar water-resistance claim.
What to put in the tank record
A controlled immersion report would identify the sample, how it was conditioned and whether each closure was assembled as supplied. A missing cover or a visibly damaged seal deserves a photograph before the run. Mark the depth reference and use a fixture that holds the intended orientation without pressing on the seam. Record water and sample temperatures because a temperature difference can affect internal pressure. Identify the liquid used and the elapsed time at the specified depth. Logging insertion and removal separately allows an editor to verify the duration of the exposure rather than relying on the wall clock visible at the start of a video.
It also pays to distinguish operating conditions. A sample powered off in a tank and one operating through a mode change answer different questions. A test report needs to identify which condition the relevant procedure specifies and which condition the lab chose for any additional trials. A protocol can document the state of a charging cover without extrapolating to charging while wet. Charging introduces its own interfaces and electrical conditions. Instructions for handling those interfaces are part of the product record a reader needs. They should be cited directly if the publication discusses them.
Counting a pass takes more than a working light
A case that still lights up immediately after removal has passed a functional spot check. The observation leaves open whether water entered a cavity, whether the amount was harmful under the applicable criteria, and whether a delayed fault developed. A criterion for ingress should be fixed before an editor sees the results. The lab needs to describe its inspection method and what constitutes failure under that method. A gain in mass, for instance, can reflect a droplet retained around a button after the exterior is dried. A stable mass can miss a quantity of water below the balance's resolution.
If a specimen must be opened for inspection, later trials on the same enclosure no longer start from the as-supplied condition. A careful experiment can reserve separate units for repeated exposures and destructive examination. That separation costs samples, but it prevents the act of inspecting one seal from becoming an invisible change to the next test. For a press story a simple sample flow is enough: how many units arrived, how many entered each condition, how many completed it and how each was inspected. An early withdrawal belongs in that flow even if the lab never assigned it a pass or fail.
How to report a harder second trial
A deliberate stress trial beyond a declared condition can reveal a failure mode, provided the baseline and challenge stay distinct. Repeating immersion after abrasion tests a product that has suffered abrasion. Holding an enclosure deeper tests increased pressure. Introducing detergent or increasing temperature changes the liquid or environment. Changing all four together may produce a striking image, but it gives the reader little basis for identifying which change mattered. A second, matched unit kept at the original condition can help distinguish deterioration during the challenge from an inconsistency present at the start.
The part most likely to disappear in a short review is what happened after the sample dried. A follow-up inspection at a named interval could uncover residue or a control problem absent at first removal. Repeating the same documented function check gives the follow-up some meaning. Turning on a different mode and announcing that the unit recovered would leave the initial problem unresolved. These observations belong under the additional trial and the actual sample count. They should never be folded back into the manufacturer's class as though the standard had required the newsroom's extra procedure.
What the chart lets an editor quote
Two named retail specifications map to two distinct forms of water exposure. Both product-to-class mappings can be traced to the seller and the class definitions to the IEC. The desk has no individual test outcome for either product. A caption that identifies each claimed class and the exposure it addresses can therefore be reproduced as printed. A capsule reading “both passed the bath test” would introduce an event absent from the sources. For someone comparing a directed rinse with accidental immersion, the difference is the substance of the story and the reason to keep the letter and numeral attached to each model.